logo binh an
Thiết bị điện Bình An

Thiết bị đóng cắt Hitachi : Contactor

Lượt xem: 4107

Giá bán: Liên hệ

Frame 20 25 35 50 65C
TYPE Electromagnetic contactor without enclosure Non- reversible H20 H25 H35 H50 H65C
Reversible H20-R H25-R H35-R H50-R H65C-R
Electromagnetic starter Without enclosure Non-reversible B)H20-T B)H25-T B)H35-T B)H50-T H65C-T
Reversible B)H20-RT B)H25-RT B)H35-RT B)H50-RT H65C-T
With enclosure Non-reversible B)SH20-T B)SH25-T B)SH35-T B)SH50-T SH65CR-T
Reversible B)SH20-
RT
B)SH25-
RT
B)SH35-
RT
B)SH50-
RT
SH65C-
RT
Thermal overload relay TR20B-1E TR25B-1E TR50B-1E TR50B-1E TR80B-1E
Rated insulation voltage AC660V
Max. rated capacity of motor JIS and JEM Rated operational current (A)
AC3
200-220V 20(18) 26 35 50(48) 65
380-440V 17 24 32 47 65
500-550V 12 12 26 37 52
Three-phase motor (kW)
AC3 and AC2
200-220V 4(3.7) 5.5 7.5 11 15
380-440V 7.5 11 15 22 30
500-550V 7.5 7.5 15 22 30
IEC Rated operational current (A)
AC3
220-240V 22(20) 27 39 52(48) 65
380-440V 22(20) 24 37 47 65
500-550V 12 12 26 37 52
Three-phase motor (kW)
AC3
220-240V 5.5 *7.5 11 15(11) 18.5
380-440V 11 11 18.5 22 30
500-550V 7.5 7.5 15 22 30
Single-phase motor (kW) AC3
JIS, JEM and IEC
100-110V 0.75
200-220V
Inching (kW) AC4
(Inching ratio 50%, electrical life 0.1 million times)
JIS, JEM and IEC
200-240V 2.2 3.7 5.5 7.5 9
380-440V 3.7 5.5 7.5 11 15
Rated capacity for resistance load (A)
AC1 (Electrical life 0.5 million times)
JIS, JEM and IEC
200-240V 32 35 50 70 80
380-440V 32 35 50 70 80
Rated thermal current (1th) A Without enclosure 32 35 50 70 80
With enclosure 26 35 44 60 65
Characteristics
of
operation coil
Coil burden (max.) (V.A)
50/60Hz
Pick-up 90/80 165/150 165/150 220/190
Hold-in 14/11 16/12 16/12 18/14
Coil comsumption (W) (Mean) 3.5 4.5 4.5 6
Pick-up voltage (% of rated voltage) (Mean) 68 73 73 75
Drop-out voltage (% of rated voltage) (Mean) 53 53 53 58
Operating time (ms)
(reference value)
Pick-up 10-20 10-20 10-20 10-20
Drop-out 10-35 10-25 10-25 10-30
Auxiliary contact specification Number Standard 1NO 1NC 2NO2NC 2NO2NC
Maximum 4NO4NC (3NO3NC... Reversible)
Rated operational current (A) 200-240V 2 (Twin contact)
380-440V 1 (Twin contact)
Rated themal current (A) 10 (Twin contact)
Application models With mechanical interlock
With 2E themal overload relay
With three-element themal overload relay
With latch
DC operation
DIN rail mounting